Federal Communications Commission FCC 96- 326


ANSI C95.1- 1982 RADIO FREQUENCY PROTECTION GUIDES
Frequency
Range
(MHz)
Electric Field
Strength E**2
(V**2/m**2)
Magnetic Field
Strength
H**2(A**2/m**2)
Power Density (S) E- field; H- field
(mW/cm**2)
Averaging Time
(minutes)
E**2; S; or H**2
30-300
300-1500
1500-100,000
6175
4,000
4,000 (f/300)
20,000
20,000
0.025
0.025(f/300)
0.125
0.125
1.0
f/300
5.0
5.0
6
6
6
6

f = frequency in megahertz (MHz)
H**2 = magnetic field strength squared
AZ/ m**2 = amperes squared per meter squared
V/m = volts per meter
E**2 = electric field strength squared
V2/ m**2 = volts squared per meter squared
mW/ cm**2 = milliwatts per centimeter squared
A/m = amperes per meter


ANSI C95.1- 1992 RADIO FREQUENCY PROTECTION GUIDES - UNCONTROLLED
Frequency
Range
(MHz)
Electric Field
Strength
E(V/m)
Magnetic Field
Strength
H(A/m)
Power Density (S) E- field; H- field
(mW/cm**2)
Averaging Time
(minutes)
E**2; S
30-100
100-300
300-3000
3000-15,000
6175
27.5
27.5
--
--
--
158.3/f**(1.668)
0.0729
--
--
--
0.2
0.2
f/1500(0.2-2)
f/1500(2-10)
4.1
30
30
30
90,000/f
14.57